Welcome to ene2u.com! Shop now to enjoy the great discount from ENETOU!
RM6,337.50 RM7,180.00
KYORITSU 4202 EARTH CLAMP TESTER CURRENT DETECTION (Frequency: Approx.2400Hz)
Price RM6,337.50 RM7,180.00
Product SKU KYO-4202
Brand Kyoritsu
Availability 2
Quantity
Description
Highlight

The international standard IEC 60364-6 provides information regarding the measurement of the resistance of an earth electrode for TT, TN, and IT systems. This measurement shall be made by the Volt-Amperometric method using two auxiliary earth electrodes. The instrument that covers this requirement is the Earth Tester

Kyoritsu 4202 Earth Clamp Testers

Various useful functions are available on Android devices using Bluetooth communication

• Real-time measurements can be transferred, shown, and saved on Android devices (up to 100 measurements)
• Saved data includes measurement, GPS location, and date & time Easy to check on the map "When" and "Where" the measurement was made
• Comparator function on Android device informs when the measured value is lower/higher than the preset value

Earth /Ground resistance and Leakage current measurement functions
• The earth resistance from 0.05 to 1500 Ω can be measured without the auxiliary earth spikes in multi-earthing systems
• True RMS leakage or phase current readings from 0.1mA to 30.0A provides vital additional information in earthing networks
• Filter function offers increased immunity to electrical noise and a Noise mark appears in excessively high noisy environments

Earth resistance Auto range 20.00/200.00/1500Ω
±1.5%±0.05Ω(0.00 - 20.99Ω)
±2%±0.5Ω(16.0 - 99.9Ω)
±3%±2Ω(100.0 - 209.9Ω)
±5%±5Ω(160 - 399Ω)
±10%±10Ω(400 - 599Ω)
AC current (50Hz/60Hz) Auto range Values are displayed, but accuracy isn't guaranteed(600 - 1580Ω)
100.0/1000mA/10.00/30.0A
±2%±0.7mA(0.0 - 104.9mA)
±2%(80mA - 31.5A)
Operating indication Earth resistance function :
Constant voltage injection
Current detection (Frequency: Approx.2400Hz)
Dual Integration
AC function: Successive approximation
Over-range indication "OL" is displayed when input exceeds the upper limit of a measuring range
Response time Approx. 7 seconds (Earth resistance)
Approx. 2 seconds (AC)
Sample rate Approx. 1 times per second
Communication Interface Bluetooth Ver2.1 + EDR Class2
Current consumption Approx. 50mA (max.100mA)
Measurement time Approx.5 hours (when R6 is used) Approx. 21 hours (when LR6 is used)
Auto power-off Turns the power off about 10 minutes after the last button operation.
Conductor size Approx.Ø32mm
Applicable standards IEC 61010-1 CAT Ⅳ 300V Pollution degree2
IEC 61010-2-032, IEC 61326 (EMC)
Power source DC6V : R6(sizeAA manganese battery) x 4
or LR6 (sizeAA alkaline battery) x 4
Dimensions 246(L)×120(W)×54(D)mm
Weight Approx. 780g (including batteries)

 


 

What's in the box
LR6 x 4, Instruction manual
8304 (Resister for operation check)
9167 (Carrying case[Hard])