Price | RM338.43 |
Product SKU | A9L20500 |
Brand | Schneider Electric |
Availability | 2 |
Quantity |
|
The iPF surge arresters with “r” indication have remote transfer of the information: “surge arrester to be replaced”.
Acti 9 iPF & iPRD
Surge protection device
Acti 9 iPF K & iPRD Type 2 Surge Protection Devices protect the electrical equipment against indirect lightning strikes.
The use of Type 2 Surge Arresters is recommended in the case of non-critical power installations.
They are tested and rated according to the standardized current wave of 8/20 µs.
Withdrawable cartridges of Acti9 iPRD Surge arresters allow quick replacement of damaged devices.
It is possible to use multipolar or unipolar products for serial assembly.
The Acti9 iPRD surge arresters "r" version has dry contacts for transferring remotely the end-of-life information.
The Acti9 iPRD8 Type 3 is placed in a cascade near the loads to be protected.
They should be installed in the secondary panelboard, as soon as the distance from the incoming surge arrester is more than 10 meters, to ensure secondary protection.
With exclusive features, Acti 9 iPF & iPRD DIN rail type-2 Surge Protector Devices (SPDs) are definitely geared to absolute safety and improved continuity of service.
- Class-2 insulation: continuous safety for operators and unqualified personnel.
- VISI-TRIP: detects faulty type-2 Surge Protector Devices (SPDs) outgoers quickly and reduces intervention time.
- Maximum discharge current: 8 to 65 kA.
- Surge Protector Device (SPD)/disconnector combinations certified for short-circuit current withstand, Isc, up to 50 kA (IEC 61643-11+ A11, version 2007).
- Maximum continuous operating voltage, Uc = 340, 460 V.
- Suitable for any earthing system: TT, TN-S, TN-C, and IT.
- Fixed or pluggable Surge Protector Device (SPD).
- Multiple-pole or single-pole products for assembly.
Specifications
range of product | Acti 9 |
---|---|
product name | Acti9 iPRD |
product or component type | Surge arrester with pluggable cartridge |
device short name | IPRD20 |
device application | Distribution |
standards | EN 61643-11:2012 IEC 61643-11:2011 |
product certifications | CE |
quality labels | KEMA-KEUR NF |
poles description | 1P + N |
remote signalling | Without |
surge arrester type | Electrical distribution network |
earthing system | TT TN-S |
surge arrester class type | Type 2 |
---|---|
surge arrester technology | MOV + GDT |
[Ue] rated operational voltage | 230/400 V AC (+/- 10 %) at 50/60 Hz |
[In] nominal discharge current | Common mode: 5 kA (L/PE) Common mode: 5 kA (N/PE) Differential mode: 5 kA (L/N) |
[Imax] maximum discharge current | Common mode: 20 kA L/PE Common mode: 20 kA N/PE Differential mode: 20 kA L/N |
[Uc] maximum continuous operating voltage | Common mode: 260 V N/PE Common mode: 350 V L/PE Differential mode: 350 V L/N |
maximum [Up] voltage protection level | Differential mode <1.1 kV type 2 L/N Common mode <1.4 kV type 2 N/PE |
[Ut] temporary overvoltage | 337 V L/N 5 s withstand 1200 V N/PE 200 ms safe failure mode 442 V L/PE 5 s withstand 1453 V L/PE 200 ms safe failure mode |
disconnector device type | Associated circuit breaker IC60N 20 A curve C - Icu 10 kA Associated circuit breaker iC60H 20 A curve C - Icu 15 kA Associated circuit breaker iC60L 20 A curve C - Icu 25 kA Associated circuit breaker NG125H 63 A curve C - Icu 36 kA Associated circuit breaker NG125L 63 A curve C - Icu 50 kA Associated fuse gG 40 A - Icu 15 kA Associated fuse gG 80 A - Icu 50 kA |
9 mm pitches | 4 |
height | 85 mm |
width | 36 mm |
depth | 69 mm |
net weight | 0.211 kg |
colour | White (RAL 9003) |
[Ipe] Ground residual current | 0.6 mA 0.003 mA |
connections - terminals | Tunnel type terminal (downside) 2.5…35 mm² Tunnel type terminal (upside) 2.5…35 mm² |
tightening torque | 2.5 N.m |
1x SPD 20kA